Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dent Res J (Isfahan) ; 20: 41, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180685

RESUMO

Background: An ever-increasing demand is seen for clear aligners and transparent vacuum-formed retainers. They are esthetic and convenient. However, the biomaterials used in these appliances might pose biological safety and biocompatibility threats in terms of their bisphenol-A (BPA) release, cytotoxicity, adverse effects, and estrogenic effects. Due to the controversial results and the lack of any systematic reviews in this regard, we conducted this systematic review. Materials and Methods: Web of Science, PubMed, Cochrane, Scopus, and Google Scholar as well as references of the found articles were searched (independently by 3 researchers) up to December 22, 2021, to find studies relevant to the biocompatibility of clear aligners and thermoplastic retainers. The search keywords were a combination of the following (and more): Essix, vacuum-formed aligner, thermoplastic aligner, clear aligner, Invisalign, vacuum-formed retainer, BPA release, monomer release, cytotoxicity, estrogenicity, biocompatibility, chemical properties, and oral epithelial cell. As eligibility criteria, articles in all languages would be included as long as their text could be translated clearly using online translators or by professional translators; all types of publications (article, book, and thesis) would be included if containing relevant studies and information; they should have been on clear liners or thermoplastic retainers; and they should have been on biocompatibility, safety, cytotoxicity, or estrogenicity of clear aligners or thermoplastic retainers. There were no restrictions on the type of study (randomized clinical trials, experimental in vitro studies). Studies focusing merely on the mechanical properties of clear aligners or thermoplastic retainers (without examining their chemical properties) would be excluded. The risk of bias was assessed. Results: The risk of bias was rather low. However, the methodologies of the studies were quite different. Overall, 16 articles (1 randomized clinical trial and 15 in vitro studies) were identified. The data for BPA release were reported in four articles (1 clinical trial and 3 in vitro studies). Quantitatively speaking, the amount of released BPA reported by in vitro studies was very low, if not zero. However, the BPA level was very high in the only randomized clinical trial. Many adverse effects were linked to using clear aligners or transparent retainers, including pain and soft-tissue issues such as burning, tingling, sore tongue, lip swelling, blisters, ulceration, dry mouth, periodontal problems, and even systemic problems such as difficulty in breathing. Besides these biological adverse effects, oral dysfunctions and speech difficulties and tooth damage may be associated with clear aligners and should as well be taken into consideration. Conclusion: Given the very high levels of BPA leach observed in the only clinical trial and considering other possible dangers of small traces of BPA (even at low doses) and also given the numerous adverse events linked to clear aligners or transparent retainers, it seems that safety of these appliances might be questionable and more clinical studies of biocompatibility are needed in this regard.

2.
Biomed Res Int ; 2022: 2595662, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36398071

RESUMO

Objectives: The jaw angle plays an important role in facial beauty. Therefore, this study is aimed at comparatively determining the range of most attractive female intergonial widths and gonial heights on Perceptometric frontal-view and three-quarter-view images, from the perspective of orthodontists, oral maxillofacial (OMF) surgeons, and laypeople of different ages and sexes. Methods: This prospective multivariate Perceptometric study was performed on 4191 esthetic scores given by 127 individuals to 33 Perceptometric face images. Frontal view and three-quarter-view photographs of a normal young woman were modified by image editing software to create two Perceptometric sets, one for the 24 gradual changes of intergonial width on the frontal view, and the other for the 9 vertical changes of the jaw angle on the three-quarter view. An online questionnaire was designed including 24 frontal and 9 oblique view photographs. The questionnaires' internal consistencies were almost perfect. Enrolled were 127 raters, including 33 orthodontists, 32 OMF surgeons, and 62 laypeople. The esthetics of different images were compared across different professions, across different ages, and between the sexes using 2-way MANCOVA, ANCOVA, and Bonferroni; the zones of esthetic jaw angles and also the sensitivity of judges to Perceptometric anatomical changes were assessed using 2-way RM-ANCOVA and Bonferroni (α = 0.05, α = 0.0056, α = 0.0021, and ß = 0.05). Results: Orthodontists and surgeons gave the highest attractiveness scores to intergonial: interzygomatic ratio of 72.53%, while the best ratio was 74.45% for the laypeople. The range of beautiful intergonial is as follows: interzygomatic ratio was 72.53% to 86.03%. OMF surgeons and orthodontists gave the highest score to a gonial height of 4.5 mm above the mouth corner, while the laypeople gave the highest score to the gonial height of 4.5 mm below the mouth corner. The range of beautiful gonial height was from 4.5 mm above the mouth corner to 9 mm below the mouth corner. The education of observers may affect their perception of beauty; orthodontists tended differ from laypeople, overall and also specifically in the case of the highly attractive frontal images concerning the intergonial width changes. However, no such differences were detected between surgeons with orthodontists or laypeople. Although age did not affect the overall esthetic scores, it did affect the sensitivity of the judges to the anatomic changes. So did expertise, i.e., the expertise of judges affected their sensitivity to anatomical changes; orthodontists showed steeper slopes of esthetic preference alterations to anatomical changes, while laypeople had the gentlest slope of preference changes. Judges' sex did not affect either their overall esthetic preferences or their sensitivity to anatomic changes. Conclusion: Narrower female jaw angles and jaw angles that are vertically close to the level of the mouth corner may be unanimously more desirable. Thus, treatments aiming at widening the jaw angle of a woman or lowering it should be discouraged, at least in Persians. Orthodontists, but not surgeons, are more sensitive than laypeople to anatomic changes of the jaw angle. The judges' age can affect this perceptive sensitivity, but their sex cannot.


Assuntos
Cirurgiões Bucomaxilofaciais , Ortodontistas , Feminino , Humanos , Psicometria , Estudos Prospectivos , Estética Dentária
3.
Oral Maxillofac Surg ; 26(2): 185-194, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34251545

RESUMO

BACKGROUND AND AIMS: The replacement of teeth with osseointegrated implants is one of the significant advances in the field of restorative dentistry. The time interval between tooth extraction and the implant can be very short or long. This systematic review and meta-analysis aimed to collect and evaluate articles related to determining the effect of instant loading of dental implants are placed in the fresh socket initial stability on the clinical success of the implant compared to delay loading dental implants. MATERIALS AND METHODS: In this study, all the available articles indexed in leading databases, including PubMed, ISI Web of Science, Embase, PsycINFO, PROSPERO, and Scopus, were searched. The full text of the articles meeting the primary criteria to be included in this research was obtained and appraised. Data of studies were extracted if they were scored as a high or moderate level of evidence. RESULTS: A total of 2258 published articles were found through electronic database searching. After screening the titles and abstracts, and full text of articles, 16 studies met the inclusion criteria and were included in the analysis. The results of this study revealed that regarding the success rate, although there was no significant difference between immediate and delayed of dental implants, immediate procedure showed a lower incidence of bone loss in single implants. CONCLUSION: Based on the results of this study, immediate loading of dental implant, under certain conditions, is a successful treatment process and is effective in reducing treatment time. Thus, immediate loading represents a valid alternative to the traditional delayed loading rehabilitation.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Humanos , Carga Imediata em Implante Dentário/métodos , Extração Dentária/métodos , Alvéolo Dental/cirurgia , Resultado do Tratamento
4.
J Prosthet Dent ; 126(6): 803.e1-803.e6, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34716011

RESUMO

STATEMENT OF PROBLEM: How multiple firing cycles may affect the oxide layer and, consequently, the shear bond strength of metal-ceramic restorations is unclear. PURPOSE: The purpose of this in vitro study was to determine the effect of multiple firings on the shear bond strength of porcelain to cobalt-chromium (Co-Cr) alloy. MATERIAL AND METHODS: Forty cylinders (Ø6.8×9 mm) of a representative presintered Co-Cr alloy (Ceramill Sintron) were prepared with computer-aided design and computer-aided manufacturing (CAD-CAM) technology. After airborne-particle abrasion and polishing, the specimens were ultrasonically cleaned of surface contaminants. A circular surface (Ø4×2 mm) was veneered on each specimen with porcelain (VM13) after 3 firings (wash opaque, opaque, and dentin). The specimens were then randomly divided into 4 groups (n=10). The normal group underwent 3 firings. The other groups underwent an additional porcelain firing: the one-plus firing group underwent 4 firings, the two-plus firing group underwent 5 firings, and the three-plus firing group underwent 6 firings. Next, the specimens were mounted in autopolymerized acrylic resin and tested in a universal testing machine and loaded at a crosshead speed of 0.5 mm/min at the metal-ceramic interface until fracture occurred. The average shear bond strength (MPa) was calculated by dividing the maximum fracture force (N) by the bonded surface of the specimens (mm2). The fracture patterns were observed microscopically and classified as adhesive, cohesive, or mixed. One-way ANOVA was used to determine differences between groups (α=.05). RESULTS: No significant differences were found among the shear bond strengths of specimens after 3, 4, 5, and 6 porcelain firings (P>.05). The mean bond strength of all groups ranged from 30 to 34 MPa. The fracture pattern of all specimens was mixed, indicating that multiple firings had no significant effect on the failure pattern. CONCLUSIONS: Multiple porcelain firings under controlled conditions had no significant effect on the fracture pattern or shear bond strength of porcelain to a presintered Co-Cr alloy.


Assuntos
Colagem Dentária , Cerâmica , Ligas de Cromo , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Resistência ao Cisalhamento , Propriedades de Superfície
5.
Dent Res J (Isfahan) ; 16(2): 71-75, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30820199

RESUMO

BACKGROUND: The degree of tooth enamel wear is an important aspect of the clinical acceptability of all-ceramic restorations. The purpose of this study was to compare the degree of enamel wear by feldspathic porcelain and polymer-infiltrated ceramic. MATERIALS AND METHODS: In this in vitro study, 10 polymer-infiltrated ceramics were prepared by creating the sections of Vita Enamic® blocks (18 mm × 14 mm × 4 mm). A total of 10 porcelain cylinders were built, and feldspathic porcelain (VMK 95, Vita) was used and fired over the metal discs. A total of 20 human maxillary premolars were assigned as antagonist. Then, 10 teeth were arranged and placed oppose to porcelain samples and 10 others were placed oppose to polymer-infiltrated-ceramic specimens in the chewing simulator. The samples were photographed before and after the chewing simulation. The difference between the two photograph was measured by stereomicroscope and Motic Image plus software 2.0 three times, and then, the mean of these three times was recorded as the amount of wear. Data were analyzed using independent samples t-test and SPSS version 16. The level of significancy was 0.05. RESULTS: The mean wear rate teeth oppose to the feldspathic porcelain group (377.294 µ) was significantly higher than that of the polymer-infiltrated ceramic group (101.755 µ) (P = 0.002). CONCLUSION: In the present study, the amount of enamel wear of the natural teeth opposed to polymer-infiltrated ceramic was significantly lower than feldspathic porcelain.

6.
J Adv Prosthodont ; 3(4): 221-8, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22259706

RESUMO

PURPOSE: Veneering porcelain might be delaminated from underlying zirconia-based ceramics. The aim of this study was the evaluation of the effect of different surface treatments and type of zirconia (white or colored) on shear bond strength (SBS) of zirconia core and its veneering porcelain. MATERIALS AND METHODS: Eighty zirconia disks (40 white and 40 colored; 10 mm in diameter and 4 mm thick) were treated with three different mechanical surface conditioning methods (Sandblasting with 110 µm Al(2)O(3) particle, grinding, sandblasting and liner application). One group had received no treatment. These disks were veneered with 3 mm thick and 5 mm diameter Cercon Ceram Kiss porcelain and SBS test was conducted (cross-head speed = 1 mm/min). Two and one way ANOVA, Tukey's HSD Past hoc, and T-test were selected to analyzed the data (α=0.05). RESULTS: In this study, the factor of different types of zirconia ceramics (P=.462) had no significant effect on SBS, but the factors of different surface modification techniques (P=.005) and interaction effect (P=.018) had a significant effect on SBS. Within colored zirconia group, there were no significant differences in mean SBS among the four surface treatment subgroups (P=0.183). Within white zirconia group, "Ground group" exhibited a significantly lower SBS value than "as milled" or control (P=0.001) and liner (P=.05) groups. CONCLUSION: Type of zirconia did not have any effect on bond strength between zirconia core and veneer ceramic. Surface treatment had different effects on the SBS of the different zirconia types and grinding dramatically decreased the SBS of white zirconia-porcelain.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...